BY DAN YAMASHITA · ASNT/PCN LEVEL 3 · SIMPLE NDT ·

What is SNT-TC-1A

SNT-TC-1A (Recommended Practice No. SNT-TC-1A) is a document published by the American Society for Nondestructive Testing (ASNT) that serves as a guideline for companies to develop their own internal programs for the qualification and certification of Nondestructive Testing (NDT) personnel.

A crucial point: SNT-TC-1A is not a standard. It is a recommended practice. This means each company has the flexibility to adapt the guidelines to its own reality, as long as those adaptations are documented in its Written Practice.

Certification performed in accordance with SNT-TC-1A is often referred to as "ASNT certification" — incorrectly. Only certificates issued directly by ASNT (such as ASNT NDT Level III or ACCP) can properly be called ASNT certification. SNT-TC-1A certification is issued by the employer, not by ASNT.

SNT-TC-1A is recognized by codes such as ASME, API, AWS, ASTM, and AMPP.

Fundamental principles

Employer responsibility

Full responsibility for certification rests with the employer. Even when external agencies (independent Level 3 consultants) are engaged for training or examination, the employer remains responsible for ensuring that these services comply with its Written Practice — and for the final certification.

In practice, many companies adopt an inadequate interpretation of this principle: they delegate full responsibility to the external Level 3 and exempt themselves from process oversight. This compromises inspector technical competence and can lead to serious problems during audits.

Controlled flexibility

Each company creates its own Written Practice describing the requirements for qualification and certification. Employers may adapt SNT-TC-1A guidelines — for example, by creating limited certifications (sub-levels) for specific scopes.

Although limiting scope is not common practice (e.g., certification valid only for butt welds), it is the employer's responsibility to understand the complexity of the inspections, know the limitations of their inspectors, and provide adequate training for each type of application.

NDT personnel levels

Level I

Performs all test steps except evaluation of results. Must receive instruction and supervision from a certified Level II or III. May segregate parts and record indications. The employer's Written Practice may allow Level I to perform and sign final acceptance, provided it is in accordance with written procedures.

Level II

Interprets procedures and standards. Performs and evaluates results in accordance with procedures. Issues test reports. May train and supervise Level I personnel and trainees.

Level III

The highest level. Responsible for establishing techniques, developing, qualifying, and approving NDT procedures. Interprets codes, standards, and specifications. Recommends the most appropriate method when not pre-established. Certifies Level I and Level II inspectors in NDT methods.

Learn more about Level 3 services: personnel qualification and procedure development.

Training and experience requirements

SNT-TC-1A defines minimum hours of formal training and supervised practical experience for each method and level. Values vary by method — ultrasonic testing and radiographic testing require significantly more hours than visual testing or liquid penetrant testing.

VT L1: 24h training
L2: 40h training
PT L1: 8h training
L2: 24h training
MT L1: 12h training
L2: 28h training
UT L1: 40h training
L2: 80h training
RT L1: 40h training
L2: 80h training
PAUT L1: 40h training
L2: 80h training

An individual may be qualified directly to Level II without prior Level I certification, provided the training and experience requirements include the combined hours for both levels.

Need training for your team? See the available training programs.

Qualification examinations

General Examination (40 questions)

Covers the basic principles of the applied method: physics, equipment, terminology, and technique fundamentals.

Specific Examination (20 questions)

Covers equipment, operating procedures, and test techniques, as well as codes, standards, specifications, and acceptance criteria applicable to the employer.

Practical Examination

The candidate demonstrates familiarity and ability to operate equipment and analyze results. At least one specimen containing a discontinuity must be tested.

Visual Acuity

Annual mandatory examination: near-distance visual acuity capable of reading Jaeger Number 1 at 12 inches (30.5 cm), natural or corrected. Additionally, color differentiation testing (typically Ishihara) and/or gray-scale discrimination for radiography.

Recertification

The interval is 5 years for all levels. Recertification requires evidence of satisfactory performance or re-examination at the discretion of the Level III. For ASME, technical performance evaluation is mandatory prior to recertification of Level I and Level II personnel.

FREQUENTLY ASKED QUESTIONS
Is it possible to obtain SNT-TC-1A certification without being employed by a company? +
No. SNT-TC-1A is based on employer responsibility. However, the system can be implemented through a legally established company of your own. For professionals without employment ties, the recommended alternative is centralized certification under ISO 9712 (PCN or equivalent).
Is SNT-TC-1A certification transferable between employers? +
No. It is the employer's responsibility and is valid only within the organization that issued it. Each company must implement its own Written Practice and conduct the qualification process according to its own needs and internal criteria.
Can an SNT-TC-1A certification be looked up on the ASNT website? +
No. SNT-TC-1A certification is not registered by ASNT or any centralized body. Only ASNT NDT Level III or ACCP certificates (administered directly by ASNT) can be verified on the ASNT website. To verify an SNT-TC-1A certification, request documentation directly from the issuing employer.
How can I verify whether an SNT-TC-1A certificate is authentic? +
Request from the issuing company: the Written Practice (referenced on the certificate), the records of the general, specific, and practical examinations, and the identification of the responsible Level III. If necessary, verify the Level III's certification directly with them or with the certifying body (ASNT, PCN, etc.).
Can an inspector certified in UT inspect any type of component? +
It depends on the Written Practice. Unlike ISO 9712 (which defines sub-levels by sector), SNT-TC-1A grants flexibility to the employer. In most cases, the Written Practice does not impose restrictions, but this does not exempt the employer from evaluating the inspector's actual competence for each application. When hiring an SNT-TC-1A certified professional, request evidence of experience relevant to the type of inspection.
SNT-TC-1A or ISO 9712: which one should I choose? +
It depends on the applicable code and client requirements. Projects based on American standards (ASME, API, AWS) generally accept or require SNT-TC-1A. Projects governed by European standards or requiring PED compliance call for ISO 9712. SimpleNDT holds both certifications and can advise on the best choice for your situation. Get in touch.

Need a Level 3 for SNT-TC-1A qualification?

Examinations, Written Practice, training, or consulting. All certified methods available.